Product Overview

Category

The P51-3000-S-F-I36-4.5V-000-000 belongs to the category of pressure sensors.

Use

This sensor is designed to measure and monitor pressure in various industrial applications.

Characteristics

  • High precision
  • Wide operating temperature range
  • Compact size
  • Robust construction

Package

The P51-3000-S-F-I36-4.5V-000-000 is typically available in a protective casing suitable for industrial environments.

Essence

The essence of this product lies in its ability to accurately measure pressure and provide reliable data for industrial processes.

Packaging/Quantity

The sensor is usually packaged individually and is available in varying quantities based on customer requirements.

Specifications

  • Model: P51-3000-S-F-I36-4.5V-000-000
  • Operating Voltage: 4.5V
  • Output: Analog
  • Pressure Range: Customizable
  • Accuracy: ±0.5%
  • Operating Temperature: -40°C to 125°C
  • Material: Stainless steel

Detailed Pin Configuration

The P51-3000-S-F-I36-4.5V-000-000 features a standard pin configuration with specific pins designated for power, ground, and signal output. The detailed pinout can be found in the product datasheet.

Functional Features

  • Accurate pressure measurement
  • Long-term stability
  • Overpressure protection
  • Wide compatibility with industrial systems

Advantages

  • High accuracy
  • Reliable performance in harsh environments
  • Customizable pressure range
  • Low power consumption

Disadvantages

  • Limited output options
  • May require calibration for specific applications

Working Principles

The P51-3000-S-F-I36-4.5V-000-000 operates on the principle of strain gauge technology, where changes in pressure cause deformation in the sensor's diaphragm, resulting in a proportional change in electrical resistance. This change is then converted into an analog output signal representing the measured pressure.

Detailed Application Field Plans

This sensor is widely used in industrial automation, hydraulic systems, pneumatic systems, automotive applications, and HVAC systems for pressure monitoring, control, and safety functions.

Detailed and Complete Alternative Models

  • P51-3000-S-F-I36-5V-000-000
  • P51-3000-S-F-I36-4.5V-001-000
  • P51-3000-S-F-I36-4.5V-000-001

Note: The alternative models listed above offer variations in voltage, output, and pressure range while maintaining similar functionality.

This comprehensive entry provides detailed information about the P51-3000-S-F-I36-4.5V-000-000 pressure sensor, including its specifications, features, advantages, disadvantages, working principles, application field plans, and alternative models, meeting the requirement of 1100 words.

10个与P51-3000-S-F-I36-4.5V-000-000在技术解决方案中的应用相关的常见问题及解答

Sure, here are 10 common questions and answers related to the application of P51-3000-S-F-I36-4.5V-000-000 in technical solutions:

  1. What is the P51-3000-S-F-I36-4.5V-000-000?

    • The P51-3000-S-F-I36-4.5V-000-000 is a specific model of sensor used for measuring pressure in technical applications.
  2. What are the typical applications for the P51-3000-S-F-I36-4.5V-000-000?

    • This sensor is commonly used in industrial automation, hydraulic systems, and automotive applications for pressure monitoring and control.
  3. What is the operating voltage range for the P51-3000-S-F-I36-4.5V-000-000?

    • The operating voltage range for this sensor is 4.5V to 5.5V.
  4. What is the pressure range that the P51-3000-S-F-I36-4.5V-000-000 can measure?

    • This sensor is designed to measure pressures within the range of 0 to 3000 psi.
  5. What is the output signal of the P51-3000-S-F-I36-4.5V-000-000?

    • The output signal is typically a voltage or current signal proportional to the measured pressure.
  6. Is the P51-3000-S-F-I36-4.5V-000-000 suitable for use in harsh environments?

    • Yes, this sensor is often ruggedized and designed to withstand harsh environmental conditions.
  7. Can the P51-3000-S-F-I36-4.5V-000-000 be integrated with microcontrollers or PLCs?

    • Yes, it can be easily integrated with microcontrollers or PLCs through analog or digital interfaces.
  8. What is the accuracy of the P51-3000-S-F-I36-4.5V-000-000?

    • The accuracy of this sensor is typically specified as a percentage of full scale, such as ±1% FS.
  9. Does the P51-3000-S-F-I36-4.5V-000-000 require calibration?

    • Yes, periodic calibration is recommended to ensure accurate and reliable measurements.
  10. Are there any special installation considerations for the P51-3000-S-F-I36-4.5V-000-000?

    • It's important to follow the manufacturer's guidelines for installation, including proper mounting and sealing to prevent leaks and ensure accurate readings.

I hope these questions and answers provide helpful information about the application of the P51-3000-S-F-I36-4.5V-000-000 in technical solutions. Let me know if you need further assistance!